CMM GANTRY | MCT NT
Liên hệ
- Vận chuyển giao hàng toàn quốc
- Phương thức thanh toán linh hoạt
- Gọi ngay +84 978.190.642 để mua và đặt hàng nhanh chóng
MÔ TẢ SẢN PHẨM
The MCT NT is also available in the NT LIGHT configuration, that is, a CMM equipped with a light aluminum alloy Z spindle and x-axis “Single Read” system.
FEATURES AND BENEFITS
- Main crossbar y made of light aluminum alloy for maximum rigidity and minimum moving mass
- Silicon Carbide Z spindle: the use of this material ensures exceptional performance in terms of rigidity and thermal stability
- Multi-sensor system for automatic compensation of errors due to thermal expansion of structural components.
- “Dual Read” system on both X-spars, enables maintenance of excellent metrological performance up to cross sections of 2500 x 1800 mm
- Spars (X-axis) with controlled expansion
- Optical lines with high resolution free expansion system (0.1µm)
- Can be equipped with a complete fairing and bellows system on the main movable structure (X / Y axes)
ENVIRONMENT
- Temperature range for metrological specifications:
Ambient temperature: 18 ÷ 22 °C
Maximum hourly gradient: 1.0 °C/h
Maximum daily gradient: 2.0 °C/24h
Maximum gradient in volume: 1.0 °C/m - Operating temperature: 15 to 35 °C
- Relative humidity for operation: 40 to 80 % (non-condensing)
- Allowable vibration: (Peak/peak acceleration)
30 mm/s2 between 1 and 10 Hz
15 mm/s2 between 10 and 20 Hz
50 mm/s2 between 20 and 100 Hz
FEEDS
- Pressure: 5.5 Bar
- Air consumption: 150Nl/min
- Power supply:
230 V ± 10%; 50 Hz ± 2% (single-phase)
115 V ±10%; 60 Hz ± 2% (single-phase)
MEASURING HEADS AND PROBES
- Manual Heads: MIH, MH20, MH20i
- Indexable Motorized Heads: PH10T, PH10M, PH10MQ, PH20, REVO
- Point-to-point touchers: TP2, TP20, TP200
- Analog keyers: SP25M
- Laser Sensors: Perceptron Laser Scanner
- Probe and tip changing systems: Automatic changing stations
PERFORMANCE
Each COORD3 CMM is tested according to UNI EN ISO 10360-2 standards.
MCT-NT
The indicated performance is valid under the following conditions:
– PH10M/PH10MQ/PH20/TP20/TP200: Ø4mm x stylus length20mm
– PH10MQ/SP25: SM1, stylus Ø 5mm x 50mm
– L= measurement length in mm
– Ambient temperature conditions:
T: 18÷22 °C; Gradients max: 1.0 °C/h – 2.0 °C/24h – 0.5 °C/m
[1] Maximum Permissible Error on length measurements according to ISO 10360-2
[2] Maximum Permissible Error on Point Grip according to ISO 10360-2
[3] Maximum Permissible Error of Point Grip on scanning according to ISO 10360-4 for SP25M/SP80 probes.
MCT NT LIGHT
The indicated performance is valid under the following conditions:
– PH10M/PH10MQ/PH20/TP20/TP200: Ø4mm x stylus length20mm
– L= measurement length in mm
– Ambient temperature conditions:
T: 18÷22 °C; Max gradients: 1.0 °C/h – 2.0 °C/24h – 0.5 °C/m
[1] Maximum Permissible Error on length measurements according to ISO 10360-2
[2] Maximum Permissible Error on point taking according to ISO 10360-2
OPTIONS
- Multi-wire wiring
- Manual/automatic pallet loading/unloading system
- PC and Printer
- Training at Coord3 center or agents
- Installation by Coord3 staff or agents
- Models and dimensions:
COORD3 MCT NT CMMs are available with the following measuring strokes (Y.Z mm):
20.10/20.15/25.18
Đánh giá