FEATURES AND BENEFITS
- Ultra-rigid mechanical structure for maximum accuracy in scanning
- Highly responsive structure to environmental temperature changes
- CAD FEA-assisted design of the extruded aluminum alloy crossmember to minimize inertial effects at maximum dynamics
- Monolithic granite support surface with integral dovetailed slide rail
- Grid of M8 holes for fixing equipment on the support surface
- Sliding system on pneumostatic pads with ultra-rigid isostatic support on all measuring axes
- Z-axis pneumatic balancing
- High-resolution (0.1-micron) carrier-scrolling optical scales with dynamic signal processing
- Digital trajectory control system for metrological performance optimization
- Hysteresis-free toothed belt drive system on all axes
- Passive environmental vibration isolation system
- Easy access to the measurement volume
- Vector positioning speed up to 866mm/sec
- Vector acceleration up to 1500mm/sec2
ENVIRONMENT
- Temperature rating for metrological performance: 20°C
- Temperature range: 18 – 22°C (extended range 16 – 26°C)
- Maximum allowable temperature gradients: 0.5°C/hour – 2°C/24 hours (extended range 5°C/24 hours)
- Operating temperature range: 15 – 35°C
- Relative humidity: 40 – 80% (non-condensing)
- Maximum ambient vibrations: 30 mm/sec2 1-10Hz | 15 mm/sec2 10-20Hz | 50 mm/sec2 20-100Hz
FEEDS
- Minimum pressure: 5 Bar -72PSI
- Compressed air consumption: 100Nl/min
- Power supply: 230v 50Hz or 110v 60Hz;
- Maximum power consumption: 10A 1200W
PERFORMANCE
Each COORD3 CMM is tested according to UNI EN ISO 10360-2 standards.
UNIVERSAL 07.07 – 09.08 – 10.08
The indicated performance is valid under the following conditions:
– PH10M/PH10MQ/PH20/TP20/TP200: Ø4mm x 10mm stylus
– PH10MQ/SP25: SM1, stylus Ø 5mm x 50mm
– REVO: RSP2/RSH175-RSP3-1/SH25-1, 20mm stylus
– L= measurement length in mm
– Ambient temperature conditions:
T1 : 18÷22°C; Max gradients: 1.0 °K/h – 2.0 °K/24h – 1.0°K/m
T2 : 16÷26°C; Gradients max: 1.0 °K/h – 5.0 °K/24h – 1.0°K/m
[1] Maximum Permissible Error on length measurements according to ISO 10360-2
[2] Maximum Permissible Error on point grip according to ISO 10360-2
[3] Maximum Permissible Error of Point Grip on scanning according to ISO 10360-4 for touch probes SP25M/SP80, ball Ø 25 mm – REVO RSP3-1
UNIVERSAL 10.09 – 10.10 – 15.10 – 15.13
The indicated performance is valid under the following conditions:
– PH10M/PH10MQ/PH20/TP20/TP200: Ø4mm x 10mm stylus
– PH10MQ/SP25: SM1, stylus Ø 5mm x 50mm
– REVO: RSP2/RSH175-RSP3-1/SH25-1, 20mm stylus
– L= measurement length in mm
– Ambient temperature conditions:
T1 : 18÷22°C; Maximum gradients: 1.0 °K/h – 2.0 °K/24h – 1.0 °K/m
T2: 16÷26°C; Gradients max: 1.0 °K/h – 5.0 °K/24h – 1.0 °K/m
[1] Maximum Permissible Error on length measurements according to ISO 10360-2
[2] Maximum Permissible Error on point grip according to ISO 10360-2
[3] Maximum Permissible Point Grip Error on scanning according to ISO 10360-4 for touch probes SP25/M/SP80/REVO, sample ball Ø 25 mm – REVO RSP3
OPTIONS
- Automatic multi-probe temperature compensation
- Active security system with volumetric scanners
- Active anti-vibration system
- Dryer
- Modular piece equipment system
- Modular protection booth
- Models and dimensions
COORD3 UNIVERSAL CMMs are available with the following measuring strokes (Y.Z mm):