CÂN PHÂN TÍCH GH-120 120×0.0001G
Liên hệ
- Vận chuyển giao hàng toàn quốc
- Phương thức thanh toán linh hoạt
- Gọi ngay +84 978.190.642 để mua và đặt hàng nhanh chóng
MÔ TẢ SẢN PHẨM
Gram | (g) | 120×0.0001 |
(mg) | 120000×0.1 | |
Decimal Ounce (oz) | 4.23×0.00001 | |
Troy Ounce (ozt) | 3.86×0.00001 | |
Pennyweight (dwt) | 77.2×0.0001 | |
Carat (ct) | 600×0.001 | |
Momme (mom) | 32.0×0.0001 | |
Grain Unit (GN) | 1852×0.002 | |
Tola (t) | 10.29×0.00001 | |
Tael (TL) | 3.20×0.00001 | |
Repeatability (Standard Deviation) | 0.1mg | |
Linearity | ±0.2mg | |
Stabilization Time (typical at FAST) | Approx. 3.5 seconds | |
Sensitivity Drift (10°C to 30°C) | ±2ppm/°C (when automatic self calibration is not used) | |
Operating Temperature | 5°C to 40°C (41 F to 104 F),85%RH or less (no condensation) | |
Display Type | Liquid Crystal Display (LCD) | |
Display Refresh Rate | 5 times/second or 10 times/second | |
Counting Mode | Minimum unit mass | 0.1mg |
Number of samples | 10, 25, 50 or 100 pieces | |
Percent Mode | Minimum 100% reference mass | 10.0mg |
Minimum 100% display | 0.01%, 0.1%, 1% (Depends on reference mass stored) | |
Standard Serial I/F | RS-232C interface with Windows Communication Tools (WinCT : included as CD-ROM) | |
Calibration Weights to be used for External Calibration | 100g | |
50g | ||
Weighing Pan | Ø90mm | |
External Dimensions | 217(W) x 442(D) x 316(H)mm | |
Power | Confirm that the adapter type is correct for the local voltage and power receptacle (Approx. 11VA) | |
Weight | Approx. 8.2kg(GH) / 7.9kg(HR-i) | |
Standard Accessories | WinCT in CD-ROM, Manual, AC Adapter |
High Performance up to 101g, 0.01mg Semi-Micro Weighing Automatic Self-Calibration (GH) and Ergonomic Design Ethernet interface (GH-08) with WinCT-Plus software makes data acquisition using multiple GH models possible expanding your Local Area Network System.
Motor-driven Internal Calibration (GH models only)
The GH internal calibration with an internal mass saves time and money. External calibration requires a great deal of skill, time and an expensive external mass. With our internal calibration with internal mass, the balance is calibrated very quickly.
- Automatic Self Calibration (GH models only)
Self-calibrates automatically when the balance detects ambient temperature changes. - One Touch Automatic Calibration (GH models only)
Allows you to calibrate the balance on demand with just the push of a button.
Standard RS-232C
Incorporates bi-directional communication with a PC, printer or other peripheral device.
Multiple Weighing Units
Uses programmable or standard units of measurement: g, mg, PCS (with ACAI* function), %, oz, ozt, ct, dwt, GN, tl, etc.
Data Memory Function (GH models only)
200 PCS Weighing data without date and time
100 PCS Weighing with date and time
50 PCS Calibration history data
GLP/GMP/GCP/ISO Compliance
Allows GLP or LIMS balance management by outputting the Balance ID number and data used to calibrate the balance. This data can be output to A&D’s AD-8121B printer or a computer, indicating date, time, Balance ID number, serial number and calibration data.
ID Number
The balance ID number can be set. It is used to identify the balance when GLP in use.
The ID number is memorized and maintained once it is fixed, even when the AC adapter is removed.
Auto Power On Function
Plug in the unit and it turns itself on without having to press the ON/OFF key.
Time & Date (GH models only)
Standard Time & Date Function complies with GLP and Interval Weighing in the Data Memory Function.
Interval Time Setting (GH models only)
Weighing intervals of 2, 5, 10, 30 seconds and 1, 2, 5, 10 minutes in the Data Memory Function.
Standard Underhook
Ideal for density determination and weighing magnetic substances.
Auto Re-Zero Function
Re-zeroes automatically after data output.
Standard Windows Communication Tools Software
A free copy of WinCT – A&D’s powerful and flexible data collection software tool for virtually instant connection to a PC and a network of other devices.
Quick USB Interface (GH-02)
Easy-to-use optional USB interface, with no driver or software installation necessary, for transfer of weighing data to a computer (Unidirectional communication from a balance to a PC only. Please use the standard RS-232C interface for sending commands from a PC to the balance.)
Ethernet Interface (GH-08) with WinCT-Plus software (CD-ROM)
WinCT-Plus software makes it possible for the user to easily set up an IP address, subnet mask etc. The user can also send commands to control and acquire data from multiple GH balances.
AD-1683 Static eliminator
The AD-1683 static eliminator, which incorporates a high-voltage power source, is a DC power-operated compact device which can eliminate static electricity from charged objects without the need of an external high-voltage power source. Since this static eliminator is compact and lightweight with no fan (no breeze is produced) and requires no high-voltage wiring, it is very easy to handle. It can generate ions very easily because it is a DC type.
Catalogue: GH_HR-i Series ENG
Đánh giá
Chưa có đánh giá nào.